Development of Digital Auto-Acu Vacuum Pump with Leak Detector / Jewel T. Arbis, Dante U. Aupe, and Antonio O. Ballester Jr.
Material type: TextPublisher: Rosario, Cavite : Cavite State University-CCAT Campus, 2018Description: xvi, 84 leaves : illustrations ; 28 cmSubject(s): Automotive vacuum pump | Leak detection | Automibiles -- Motors | Compression motor | Prototype Engineering | Cost analysisLOC classification: UM TL210 | A73 2018Summary: ARBIS, JEWEL T., AUPE, DANTE U., and BALLESTER JR, ANTONIO O., Development of Digital Auto ACU Vacuum Pump with Leak Detector. Undergraduate Design Project. Bachelor of Science in Industrial Technology. Cavite State University, Rosario Cavite. May 2017. Mr. Ariel G. Santos. Technical critic: Mr. Richard V.Dela Peña The study entitled as “Development of Digital Auto ACU Vacuum Pump with Leak Detector" was conducted at Automotive Technology Department of Cavite State University-Rosario Campus. The design, fabrication and evaluation of the prototype started last April 2016 and being conducted until May 2017. The objectives of the study was to develop and evaluate the Digital Auto ACU Vacuum Pump with Leak Detector. Specifically, the study aimed to; 1) designa Digital Auto ACU Vacuum Pump with Leak Detector, 2) construct a Digital Auto ACU Vacuum Pump with Leak Detector as to its lay-out, specification and principles of operation out of locally available materials, 3) evaluate the performance of the Digital Auto ACU Vacuum Pump with Leak Detector in terms of: a) maximum distance of leak detection; b) evacuation time refigerant/ air in the system; c) compare the performance of the two vacuum pumps. 4) compute for the fixed and variable cost of the project. The digital auto ACU vacuum pump with leak detector was designed with compressor motor with 2 hp, digital vacuum gauge, digital pressure gauge, service hose, metal frame, caster wheel and leak detector It was designed and constructed for more convenient use to perform vacuuming of the auto air-con unit. The raw materials has cost Php.14, 979 while the labor cost reached Php.500.00. The total initial cost was Php. 15,479. The digital auto ACU vacuum pump with leak detector performed effectivelyvacuuming auto ACU. Its performance was evaluated with different types of cars -singleunit compact size car, single unit medium size car and single unit SUV car with varying speed of operation in vacuuming process. It revealed that the developed prototype can detect leak in 1-3cm faster.Item type | Current location | Collection | Shelving location | Call number | Copy number | Status | Date due | Barcode |
---|---|---|---|---|---|---|---|---|
Thesis/Manuscripts/Dissertations | Cavite State University - CCAT Campus | Thesis/Manuscript/Dissertation | TH | UM TL210 A73 2018 (Browse shelf) | 1 copy | Available | T0003596 |
Browsing Cavite State University - CCAT Campus shelves, Shelving location: TH, Collection: Thesis/Manuscript/Dissertation Close shelf browser
Undergraduate Thesis (BSIT) Major in Automotive Technology--Cavite State University-CCAT Campus, 2018.
Includes bibliographical references and appendices.
ARBIS, JEWEL T., AUPE, DANTE U., and BALLESTER JR, ANTONIO O., Development of Digital Auto ACU Vacuum Pump with Leak Detector. Undergraduate Design Project. Bachelor of Science in Industrial Technology. Cavite State University, Rosario Cavite. May 2017. Mr. Ariel G. Santos. Technical critic: Mr. Richard V.Dela Peña
The study entitled as “Development of Digital Auto ACU Vacuum Pump with Leak Detector" was conducted at Automotive Technology Department of Cavite State University-Rosario Campus. The design, fabrication and evaluation of the prototype started last April 2016 and being conducted until May 2017. The objectives of the study was to develop and evaluate the Digital Auto ACU Vacuum Pump with Leak Detector. Specifically, the study aimed to; 1) designa Digital Auto ACU Vacuum Pump with Leak Detector, 2) construct a Digital Auto ACU Vacuum Pump with Leak Detector as to its lay-out, specification and principles of operation out of locally available materials, 3) evaluate the performance of the Digital Auto ACU Vacuum Pump with Leak Detector in terms of: a) maximum distance of leak detection; b) evacuation time refigerant/ air in the system; c) compare the performance of the two vacuum pumps. 4) compute for the fixed and variable cost of the project.
The digital auto ACU vacuum pump with leak detector was designed with compressor motor with 2 hp, digital vacuum gauge, digital pressure gauge, service hose, metal frame, caster wheel and leak detector It was designed and constructed for more convenient use to perform vacuuming of the auto air-con unit. The raw materials has cost Php.14, 979 while the labor cost reached Php.500.00. The total initial cost was Php. 15,479.
The digital auto ACU vacuum pump with leak detector performed effectivelyvacuuming auto ACU. Its performance was evaluated with different types of cars -singleunit compact size car, single unit medium size car and single unit SUV car with varying speed of operation in vacuuming process. It revealed that the developed prototype can detect leak in 1-3cm faster.